Summary
Pediatric VAD bridge to retransplant is rare and has been little studied, even as device support before a first heart transplant has grown common over the past two decades.
Researchers reviewed the ACTION registry and identified 24 children who received a ventricular assist device while awaiting a second heart transplant, supported for a median of 64 days. Thirteen received a device to help them become candidates for retransplant, and 11 as a bridge to a retransplant for which they were already listed.
Complications were common. Eighteen of the 24 developed an infection, 10 had bleeding, 8 required dialysis, and 2 had a stroke. Despite this, 17 reached retransplant, and survival one year afterward was 88%.
Deaths while on device support were more frequent among children implanted to establish candidacy than among those already listed for retransplant.
The authors describe this as the first multicenter look at the approach and conclude that waitlist and post-retransplant survival were favorable despite the high rate of adverse events.
This ACTION study was published online ahead of print in ASAIO Journal on November 17, 2026. Congratulations to the authors:
- Stevan Lukich
- Hanna J. Tadros
- Joseph A. Spinner
- Anna Joong
CITATION
Lukich S, Tadros HJ, Spinner JA, Joong A. Ventricular assist devices effectively bridge pediatric patients to heart retransplantation: an ACTION registry study. ASAIO J. Published online November 17, 2026. doi:10.1097/MAT.0000000000002921